The plug-in currently is recognized and initialized inside of HomeSeer with no problems, so hopefully I'll have something working within a few weeks or months :-D. Good luck with the plug-in. December 29, , PM.
I'm hoping your plug-in efforts are going well. So I wish you luck and if you need a Beta tester let me know. December 30, , PM. Mark HS3 Pro 3. Originally posted by mnsandler View Post. January 2, , AM. A minor update on status and other stuff Hi all, As someone else pointed out, the ICM should work with any Vista panel, so the Vista 20 should work. As far as getting it under HomeSeer, there are a few things that I'm discovering as I'm creating this plugin.
So, if you are interested in these things, as far as automation goes, then the ICM may not be the best choice. Determine which user armed or disarmed the system Occasionally the system will bypass zones on it's own and you won't know which ones are bypassed. They also happen so fast that if your zone name alpha in the panel is longer than what fits on one line it may get missed. The ICM gets messages one line at a time and sometimes the fault is so fast that you only get one line so don't know which device faulted in the case of motion.
I'm sure there are other caveats that I'm either forgetting or will run into still In regards to where I am on the plug-in, check out the attached screenshot assuming I attached it correctly. This is all live data coming from the ICM at this point. I'm also getting zone status messages but currently not processing them. So, it's well on it's way, and if demand is high enough I'll release a 1. I will keep everyone posted and feel free to shoot me any questions.
I will also have some questions in regards to how people might want certain features to work like low battery and zones in check. Regards, Chris Attached Files. January 2, , PM. Originally posted by jkarney View Post. Firmware upgrades come from Honeywell. I have attached firmware upgrade page from the install manual. I'm not sure what effect on security this would have. Sound Must be 1 for UL installations. Standard setting for U. Each schedule consists of one time window programmed using the Time-Driven Event for openings and one time window for closings.
Refer Timed Events? Temporary schedules are programmed separately, using the 81 The following worksheet is an example of the worksheet found in the Programming Guide. Auto bypass — Zone list Zone list Enter the code for the desired action and Auto unbypass — Timed Events? As the number is keyed in, the 01 Time Window? Enter the first time-window number for this access schedule for the displayed day. Zone trouble operating on battery power only. Technical Support These limits are designed to provide reasonable protection against harmful interference in a residential installation.
A-4 Duress Reporting Page Ground Start Module Page Time Driven Events Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a vari- ety of reasons.
Page WWW. This manual is also suitable for: Vistapul. Print page 1 Print document pages. Rename the bookmark. Delete bookmark? Take this into consideration when determining mounting location. The TM must be located between one and two feet from the or receiver's antennas.
The TM must not be installed within the control cabinet. If using series wireless systems, the DIP switches on the transmitters must match the system House ID programmed into the control. The House ID will be the same for all transmitters and must match the House ID programmed into the system via Device Programming for the wireless receiver. For series transmitters, each response type uses a certain range of zone numbers. Page Series Transmitter Setup Series Transmitter Setup series transmitters have built-in serial numbers that must be "learned" by the system using the 93 Menu mode programming, or input to the control via the downloader.
Do not install batteries in wireless transmitters until ready to learn, as will be indicated under Programming the Wireless Transmitters later in this section. Though it is not critical to remove batteries after learning, it is recommended in order to avoid interference while learning additional transmitters.
Page Programming Wireless Transmitters Programming Wireless Transmitters Zone number assignments can be from for series transmitters, and for series transmitters, except for zone 64, which is reserved for a wireless keypad.
Page 65 Each zone in a system must be assigned a zone 10 Zone Type type, which defines the way in which the system Zone disabled 00 responds to faults in that zone. Enter the zone response type for each zone. Fault the and A restore the transmitter faulting is accomplished by pressing the appropriate button for button type transmitters, or by opening and closing zone sensors for other transmitters. Testing in this mode assists in determining good mounting locations for the transmitters and verifies that the RF transmission has sufficient signal amplitude margin for the installed system.
Page 71 a. These conditions apply only when a zone list is used. The following options are available: a. Enter 0 no group or for a specific group number.
If a Zone List number was used to start or stop a relay, you must define the zones belonging to that list as follows: Enter the zone list number When mounting the VIP Module outside the cabinet, use the screw holes at the rear to mount horizontally or vertically 2-faced adhesive tape may be used, if preferred.
Page Aav Module Operation Section Please be advised that if this option is selected, it may defeat modem download and VIP module remote access capability.
Output 1 may be used to trigger an optional Ground Start module for installations having telephone lines which require ground start instead of loop start operation to obtain dial tone from the telco central office. When the panel has a message to transmit to the central station, it will seize the line, go off hook, and then trigger the module to connect the "RING" Page Section External Sounders Section Page Non-Ul Installations mA is supplied by the battery. The AB12 bell should be wired as shown in Figure Can be wired for either a steady or yelp sound and is rated at dB 10 feet.
This siren can also be tamper protected, or can be mounted in a metal cabinet , which can be tamper protected. Page Programming Event Log Options 1. You can use a longer cable or an extension cable if the Control and serial printer are separated by more than 10 feet.
Page 97 Press [1] if Event Log is to be cleared from memory. Page Transformer And Battery Connections 60 Hz Outlet against blowing the 3 years fuse inside the transformer non- replaceable. Most false alarms occur either upon exiting the premises, or because of a zone which tends to go into alarm either due to environmental factors, or because the zone's resistance to the control may be on the edge of acceptability. Page Cross Zoning Cross-Zoning The Cross-Zoning feature is designed so that a combination of two zones must be faulted within a five minute period to cause an alarm on either zone.
This prevents momentary faults from causing an alarm condition. You can select four "sets" The following table lists the zone numbers and the types of sensors that can be used with each in this system: Zone Sensors If you have followed earlier instructions during the installation of the various devices, many of these fields will already have been programmed.
Requires the use of zone 7 wired loop zone 7 no longer available as protection zone when used for keyswitch operation. Note that multiple alarm soundings will not occur more frequently than allowed by the programmed alarm sounder duration. This selection applies to local sounding and has no impact on the number of communication messages transmitted. Page If selecting touch-tone, make sure the subscriber has requested and is paying for touch-tone service. Note that whether or not touch-tone dialing for call placement is permitted, communication by the use of DTMF signaling Ademco High Speed will still take place.
This field is applicable only if downloading will be utilized. Page This field selects the reporting format for use on the primary telephone number. Note that selection applies to both primary and secondary phone numbers. Can only arm lobby if all other affecting partitions are armed. Enter times 2 hours hours. Failure of a receiver to receive any RF signal within the time entered will result in activation of the response type programmed for zone 90 for the first receiver and zone 88 for the second receiver and their related communication reports.
Enter 0 if the display should remain unlit unless a key is pressed. The backlighting then turns off again after a period of keypad inactivity. Enter 0 if the button is not to be used to global arm the system however, home partition arming will still occur.
Enter 00, 00 if daylight savings time does not apply to the user's region. Standard setting for U. Enter 1 to allow the system to be disarmed outside the programmed disarm opening window if an alarm has occurred.
Enter 0 to allow disarming only during the disarm window, regardless of system status. Pressing 0 will display the next choice in sequence. Fault and restore A the transmitter or polling loop device twice. The keypad will beep twice when it hears the first transmission, and three times when it hears the second. Page a Press [ ] followed by the 3 digit number of the first word from the fixed dictionary shown later in this section e.
Press [6] in order to accept the word and proceed, or press [8] to store the complete descriptor and exit, or Page When the desired character appears, press the [6] key to select it. The cursor will then move to the right, in position for the next character. Press [ ] plus the two digit entry for the next letter of the word. Page Custom Message Display Installer's Message Normally, when the system is in the disarmed state, the following display is present on the keypad.
To select a word, press [ ] followed by the word's 3-digit number. NOTE: This vocabulary is not to be used for relay voice descriptors. Page Device Programming Device Programming This menu is used to program keypads, receivers and relay modules. This substitute word will be announced by the VIP module in place of the custom word that is displayed on the alpha keypad. For example, an alarm display of "John's Bedroom"